“A big thank you to the team at Southern Rewind for getting my hot tub pump and motor up and running . Great job Guys.”
Baldor®
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — Baldor® Triple Rate
Source
Max HP
L1 (1 – 12)
L2 (2 – 10)
L3 (3 – 11)
Med HP
L1 (1)
L2 (2)
L3 (3)
Min HP
L1 (1)
L2 (2)
L3 (3)
Insulate Separate
7/8/9
Med HP
4/5/6/7/8/9
Min HP
4/5/6
Applications:
Rating
All
Original DWG
GE® 1
Connection Diagram for GE®
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — GE® Triple Rate
Source
Max HP
L1 (1 – 6)
L2 (2 – 4)
L3 (3 – 5)
Med HP
L1 (1)
L2 (2)
L3 (3)
Min HP
L1 (1)
L2 (2)
L3 (3)
Insulate Separate
7/8/9
Applications:
Rating
25/20/15
Original DWG
GE® 2
Additional Connection Diagram for GE®
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — GE® Triple Rate
Source
Max HP
L1 (1 – 5)
L2 (2 – 6)
L3 (3 – 4)
Med HP
L1 (4)
L2 (5)
L3 (6)
Min HP
L1 (1)
L2 (2)
L3 (3)
Insulate Separate
Max HP
7/8/9
Applications:
Rating
15/10/7.5
Original DWG
Toshiba
Connection Diagram for Toshiba
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — Toshiba Triple Rate
Source
Max HP
L1 (T1 – T6)
L2 (T2 – T4)
L3 (T3 – T5)
Med HP
L1 (T1)
L2 (T2)
L3 (T3)
Min HP
L1 (T4)
L2 (T5)
L3 (T6)
Insulate Separate
Max HP
Applications:
Rating
15/10/7.5
Original DWG
Toshiba 2
Additional Connection Diagram for Toshiba
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — Toshiba Triple Rate
Source
Max HP
L1 (T1 – T6)
L2 (T2 – T4)
L3 (T3 – T5)
Med HP
L1 (T1)
L2 (T2)
L3 (T3)
Min HP
L1 (T1)
L2 (T2)
L3 (T3)
Insulate Separate
Max HP
Med HP
Min HP
T7/T8/T9
Applications:
Rating
20/15/10 HP
25/20/15 HP
30/25/20 HP
40/30/25 HP
50/40/30 HP
60/50/40 HP
75/60/50 HP
100/75/60 HP
Original DWG
S-7072367
SAME
SAME
SAME
SAME
SAME
SAME
SAME
Weg
Connection Diagram for WEG
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — WEG Triple Rate
Source
Max HP
L1 (T1,T5)
L2 (T2,T6)
L3 (T3,T4)
Med HP
L1 (T4)
L2 (T5)
L3 (T6)
Min HP
L1 (T1)
L2 (T2)
L3 (T3)
Insulate Separate
Max HP
7/8/9
Applications:
Rating
All
Original DWG
Vintage Westinghouse
Connection Diagram for Vintage Westinghouse
If you have additional questions after reviewing the diagram below, please Contact Us.
Connection Diagram — Vintage Westinghouse Triple Rate
Source
Max HP
L1 (1 – 12)
L2 (2 – 10)
L3 (3 – 11)
Med HP
L1 (1)
L2 (2)
L3 (3)
Min HP
L1 (1)
L2 (2)
L3 (3)
Insulate Separate
Max HP
Applications:
Rating
All
Original DWG
If you have additional questions, or would like to contact us about our services, please don't hesitate to GIVE US A CALL TODAY.